Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Sci Rep ; 12(1): 17194, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-36229488

RESUMO

Antibodies can prevent malaria by neutralizing the infectious Plasmodium falciparum sporozoites (SPZ) before they establish an infection in the liver. Circumsporozoite protein (CSP), the most abundant surface protein of SPZ is the leading candidate for passive (and subunit) immunization approaches against malaria. Comprehensive assessment of the parasite-inhibitory capacity of anti-CSP monoclonal antibodies (mAbs) is an important step in advancing CSP-based immunization strategies. In this study, we employed a quantitative imaging-based motility assay to quantify the effect of anti-CSP mAbs on SPZ motility, both in vitro and in human skin.Our assay provided a quantitative measure of mAb parasite-inhibitory capacity through measurement of the half-maximal motility inhibitory concentration (IC50M) value for anti-CSP mAbs (IC50M 2A10: 24 nM, IC50M 3SP2: 71 nM). We found a sevenfold discrepancy between the IC50M and the binding saturation concentration measured by ELISA, possibly related to the observed shedding of CSP-mAb complexes during SPZ movement. In a subset of SPZ (5%), in vitro motility was unaffected by the presence of 2A10 while 3SP2 was able to completely block movement. In our ex vivo skin explant model, SPZ proved less susceptible to anti-CSP mAbs compared to SPZ in an in vitro environment. By quantitatively assessing motility, we created a valuable tool that can be used for comprehensive assessment of anti-CSP mAb potency. Insight that will help deepen our understanding of anti-CSP mAb potency and guide selection of the most promising anti-CSP mAbs for downstream clinical development.


Assuntos
Vacinas Antimaláricas , Malária Falciparum , Malária , Animais , Anticorpos Monoclonais/farmacologia , Anticorpos Antiprotozoários , Humanos , Malária/prevenção & controle , Proteínas de Membrana , Plasmodium falciparum , Proteínas de Protozoários , Esporozoítos
2.
Int J Oral Maxillofac Surg ; 51(10): 1318-1329, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35165005

RESUMO

Image-to-patient registration in navigated mandibular surgery is complex due to the mobile nature of the mandible compared with other craniofacial bones. As a result, surgical navigation is rarely employed in the mandibular region. This systematic review provides an overview of the different registration methods that are used for surgical navigation of the mandible. A systematic search was performed in the MEDLINE Ovid, Scopus, and Embase databases on March 25, 2021. Search terms included synonyms for mandibular surgery, surgical navigation, and registration methods. Articles about navigated mandibular surgery, where the registration method was explicitly mentioned, were included. The database search yielded a total of 2952 articles, from which 81 articles remained for analysis. Four main registration methods were identified: point registration, surface registration, hybrid registration, and computer vision-based registration. The mobility of the mandible is accounted for by either keeping the mandible in a fixed position during preoperative imaging and surgery, or by tracking the mandibular movements. Although different registration methods are available for navigated mandibular surgery, there is always a trade-off between accuracy, registration time, usability, and invasiveness. Future studies should focus on testing the different methods in larger patient studies and should report the registration accuracy.


Assuntos
Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Cirurgia Assistida por Computador/métodos
3.
mSphere ; 6(2)2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33827910

RESUMO

Malaria vaccine candidates based on live, attenuated sporozoites have led to high levels of protection. However, their efficacy critically depends on the sporozoites' ability to reach and infect the host liver. Administration via mosquito inoculation is by far the most potent method for inducing immunity but highly impractical. Here, we observed that intradermal syringe-injected Plasmodium berghei sporozoites (syrSPZ) were 3-fold less efficient in migrating to and infecting mouse liver than mosquito-inoculated sporozoites (msqSPZ). This was related to a clustered dermal distribution (2-fold-decreased median distance between syrSPZ and msqSPZ) and, more importantly, a 1.4-fold (significantly)-slower and more erratic movement pattern. These erratic movement patterns were likely caused by alteration of dermal tissue morphology (>15-µm intercellular gaps) due to injection of fluid and may critically decrease sporozoite infectivity. These results suggest that novel microvolume-based administration technologies hold promise for replicating the success of mosquito-inoculated live, attenuated sporozoite vaccines.IMPORTANCE Malaria still causes a major burden on global health and the economy. The efficacy of live, attenuated malaria sporozoites as vaccine candidates critically depends on their ability to migrate to and infect the host liver. This work sheds light on the effect of different administration routes on sporozoite migration. We show that the delivery of sporozoites via mosquito inoculation is more efficient than syringe injection; however, this route of administration is highly impractical for vaccine purposes. Using confocal microscopy and automated imaging software, we demonstrate that syringe-injected sporozoites do cluster, move more slowly, and display more erratic movement due to alterations in tissue morphology. These findings indicate that microneedle-based engineering solutions hold promise for replicating the success of mosquito-inoculated live, attenuated sporozoite vaccines.


Assuntos
Culicidae/parasitologia , Injeções Intradérmicas/métodos , Mordeduras e Picadas de Insetos/parasitologia , Plasmodium berghei/fisiologia , Esporozoítos/fisiologia , Seringas , Animais , Sistemas de Liberação de Medicamentos , Feminino , Fígado/parasitologia , Malária/prevenção & controle , Vacinas Antimaláricas/administração & dosagem , Camundongos , Movimento , Vacinas Atenuadas/administração & dosagem
4.
Biomater Sci ; 9(5): 1683-1690, 2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33410436

RESUMO

AIM: Pre-targeting is a proven strategy for in vivo delivery of a diagnostic or therapeutic payload. The pre-targeting concept can be realized through various conjugation strategies, one of which is based on copper-free "click" chemistry. Copper-free click reactions have shown in vivo potential for imaging and radionuclide therapy, but this conjugation strategy has not yet been explored in combination with microspheres or unicellular organisms. This study aims to evaluate the in vivo efficacy of strain-promoted azide-alkyne cycloaddition (SPAAC) reactions to achieve imaging and targeting of azide-functionalized macro-aggregated albumin (MAA) microspheres and Staphylococcus aureus bacteria. METHODS: MAA microspheres (diameter 10-90 µm) were functionalized with a biorthogonal Cy5 fluorophore, bearing an azide functionality (N3), to generate MAA-Cy5-N3. S. aureus (diameter ∼1 µm) were functionalized with 99mTc-UBI29-41-Cy5-N3, generating S. aureus-99mTc-UBI29-41-Cy5-N3. In situ and in vitro click conjugation on the -N3 moieties was studied for 20 h using a radioactivity-based assay and fluorescence microscopy. For in vivo validation, both primary entities, radiolabeled with 99mTc, were deposited into the microvasculature of the liver via intrasplenic injections. Secondary targeting was realized following the intravenous administration of indium-111-radiolabeled diethylenetriaminepentaacetic acid-dibenzocyclooctyne (111In-DTPA-DBCO). To assess click reaction efficiency in vivo, 99mTc and 111In-biodistributions were measured (SPECT and %ID g-1). Use of 111In-DTPA-DBCO in mice without MAA deposits or mice infected with non-functionalized S. aureus served as controls. Ex vivo confocal fluorescence imaging was carried out in excised tissues to confirm the presence of functionalized MAA and bacteria. RESULTS: In vitro data confirmed effective click reactions on both the MAA particles and the bacterial membrane. SPECT imaging and biodistribution studies revealed significantly (p < 0.05) increased accumulation of 111In-DTPA-DBCO at the sites where MAA-Cy5-N3 (7.5 ± 1.5%ID g-1vs. 3.5 ± 0.5%ID g-1 in control mice) and S. aureus-99mTc-UBI29-41-Cy5-N3 (9.3 ± 1.3%ID g-1vs. 6.0 ± 0.5%ID g-1 in control mice) resided. Ex vivo fluorescence imaging confirmed the presence of either functionalized MAA or S. aureus in excised spleens and livers of mice. CONCLUSION: Copper-free click chemistry between a DBCO moiety and Cy5-N3-functionalized microspheres or bacterial entities in the liver can be used to realize in vivo imaging and targeting.


Assuntos
Química Click , Medicina Nuclear , Animais , Camundongos , Microesferas , Staphylococcus aureus , Distribuição Tecidual
5.
World J Urol ; 38(4): 883-896, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31286194

RESUMO

PURPOSE: The aim of the present study is to investigate the impact of the near-infrared (NIRF) technology with indocyanine green (ICG) in robotic urologic surgery by performing a systematic literature review and to provide evidence-based expert recommendations on best practices in this field. METHODS: All English language publications on NIRF/ICG-guided robotic urologic procedures were evaluated. We followed the PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analyses) statement to evaluate PubMed®, Scopus® and Web of Science™ databases (up to April 2019). Experts in the field provided detailed pictures and intraoperative video-clips of different NIRF/ICG-guided robotic surgeries with recommendations for each procedure. A unique QRcode was generated and linked to each underlying video-clip. This new exclusive feature makes the present the first "dynamic paper" that merges text and figure description with their own video providing readers an innovative, immersive, high-quality and user-friendly experience. RESULTS: Our electronic search identified a total of 576 papers. Of these, 36 studies included in the present systematic review reporting the use of NIRF/ICG in robotic partial nephrectomy (n = 13), robotic radical prostatectomy and lymphadenectomy (n = 7), robotic ureteral re-implantation and reconstruction (n = 5), robotic adrenalectomy (n = 4), robotic radical cystectomy (n = 3), penectomy and robotic inguinal lymphadenectomy (n = 2), robotic simple prostatectomy (n = 1), robotic kidney transplantation (n = 1) and robotic sacrocolpopexy (n = 1). CONCLUSION: NIRF/ICG technology has now emerged as a safe, feasible and useful tool that may facilitate urologic robotic surgery. It has been shown to improve the identification of key anatomical landmarks and pathological structures for oncological and non-oncological procedures. Level of evidence is predominantly low. Larger series with longer follow-up are needed, especially in assessing the quality of the nodal dissection and the feasibility of the identification of sentinel nodes and the impact of these novel technologies on long-term oncological and functional outcomes.


Assuntos
Corantes , Verde de Indocianina , Imagem Óptica , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Urológicos/métodos , Consenso , Humanos , Imagem Óptica/normas , Guias de Prática Clínica como Assunto , Procedimentos Cirúrgicos Robóticos/normas , Cirurgia Assistida por Computador/normas , Procedimentos Cirúrgicos Urológicos/normas
6.
Eur J Nucl Med Mol Imaging ; 46(12): 2558-2568, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31377820

RESUMO

PURPOSE: Diagnostic imaging modalities have moderate sensitivity for the identification of lymph node (LN) metastases in prostate cancer (PCa) patients. Mapping the lymphatic drainage from the prostate can help to identify the LNs directly draining from the tumour (sentinel nodes (SNs)); the LNs stated to have the highest chance of containing metastatic cancer cells. Although the lymphatic drainage may differ between segments within the prostate, the location of the primary tumour is not routinely taken into account during peripheral zone-aimed tracer administration. This study evaluates whether linking the SN procedure to the primary cancer deposits increases the identification accuracy of lymphatic metastases. METHODS: Sixty-seven PCa patients, scheduled for robot-assisted laparoscopic prostatectomy (RALP) and extended lymph node dissection (ePLND) with subsequent SN biopsy, were included in this retrospective study. After injection of the hybrid tracer ICG-99mTc-nanocolloid in the prostate, SN mapping was performed based on lymphoscintigraphy and SPECT/CT. SNs were resected using a combination of radio- and fluorescence guidance. Pathology was used to determine the primary tumour location and metastatic spread. Fluorescence imaging of paraffin-embedded prostate tissue was used to determine the location of the tracer deposits in the prostate. This deposition was related to the primary tumour location, the lymphatic drainage pattern of the injected tracer, and the metastatic spread. RESULTS: In total 265 radioactive LNs (211 SNs and 54 higher-echelon nodes in 64 patients; 4.3 LNs per patient; IQR: 2-6) were identified. In three patients (4%) preoperative imaging did not allow identification of SNs. Tumour-positive SN visualization within the pelvis was shown to be influenced by intraprostatic location of tracer administration. This could be concluded from (1) a clear correlation between lymphatic drainage to the right or left side of the body and tracer deposition on the right or left side of the prostate, (2) visualization of a higher number of LNs after dorsal tracer deposition compared with ventral tracer deposition, (3) different drainage patterns observed for tracer deposition into the base or apex of the prostate, and (4) the indication that intratumoural tracer deposition increases the chance of visualizing nodal metastases compared with extratumoural tracer deposition. CONCLUSIONS: The correlation between the location of the tracer deposits, the location of the primary tumour, and the visualization of the (tumour-positive) SNs indicated that placement of tracer deposits is of influence on the visualized lymphatic drainage pattern. This suggests that tracer injection near or into the primary tumour site is beneficial for the identification of metastatic spread.


Assuntos
Neoplasias da Próstata/patologia , Linfonodo Sentinela/cirurgia , Coloides , Humanos , Período Intraoperatório , Masculino , Metástase Neoplásica , Período Pré-Operatório , Neoplasias da Próstata/cirurgia , Traçadores Radioativos , Estudos Retrospectivos , Linfonodo Sentinela/patologia
7.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31133492

RESUMO

PURPOSE: To assess the feasibility of using freehand Single Photon Emission Computed Tomography (freehandSPECT) for the identification of technetium-99m-hydroxydiphosphonate (99mTc-HDP) positive bone lesions and to evaluate the possibility of using these imaging data-sets for augmented- and virtual-reality based navigation approaches. MATERIAL AND METHODS: In 20 consecutive patients referred for scintigraphy with 99mTc-HDP, 21 three-dimensional freehandSPECT-images were generated using a handheld gamma camera. Concordance of the two different data sets was ranked. Furthermore, feasibility of segmenting the hotspot of tracer accumulation for navigation purposes was assessed. RESULTS: In 86% of the cases freehandSPECT images showed good concordance with the corresponding part of the scintigraphic images. In lesions with a signal to background ratio (SBR) >1.36, freehandSPECT provided an automatically segmented reference point for navigation purposes. In 14% of the cases (average SBR 1.82, range 1.0-3.4) freehandSPECT images showed intermediate concordance due to difficult anatomical area or negative bone scintigraphy and could not be used as navigation targets. CONCLUSION: In this pilot study, in 86% of the cases freehandSPECT demonstrated good concordance with traditional scintigraphy. A lesion with a SBR of 1.36 or more was suitable for navigation. These high-quality freehandSPECT images supported the future exploration navigation strategies, e.g. guided needle biopsies.


Assuntos
Biópsia por Agulha/métodos , Doenças Ósseas/diagnóstico por imagem , Câmaras gama , Biópsia Guiada por Imagem/métodos , Medronato de Tecnécio Tc 99m/análogos & derivados , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doenças Ósseas/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Método Duplo-Cego , Desenho de Equipamento , Humanos , Biópsia Guiada por Imagem/instrumentação , Especificidade de Órgãos , Imagens de Fantasmas , Projetos Piloto , Compostos Radiofarmacêuticos/farmacocinética , Software , Medronato de Tecnécio Tc 99m/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imagem Corporal Total
8.
Data Brief ; 22: 50-55, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30581904

RESUMO

Far-red dyes such as cyanine 5 (Cy5) are gaining interest in (bio)medical diagnostics as they have promising features in terms of stability and brightness. Here, the electrostatic density and stacking tendency in different solvents of nine systematically altered asymmetrical Cy5 dyes are reported. In addition to this, the influence of molecular alterations on the vibronic coupling was reported. The data presented supplement to the recent study "The influence of systematic structure alterations on the photophysical properties and conjugation characteristics of asymmetric cyanine 5 dyes" (Spa et al., 2018).

9.
J Robot Surg ; 13(3): 455-462, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30178300

RESUMO

Robot-assisted radical prostatectomy (RARP) is performed in patients with prostate cancer. Unfortunately, 10-46% of patients may still suffer from limited erectile function (EF) after RARP. This study aimed to develop a prediction model based on the extent of fascia preservation (FP) and postoperative EF after RARP. A previously developed FP score quantizing the extent and regions of nerve-preservation was determined in a cohort of 1241 patients who underwent RARP. The predictive value of the FP score for post-prostatectomy EF (following the international index erectile function (IIEF) score, EF domain) was analyzed. To increase the predictive value of the scoring system, the FP regions were related to postoperative EF, nerve distribution and co-morbidity factors. Finally, a prediction model for EF was developed based on the studied cohort. When corrected for the preoperative IIEF-EF, the FP score was shown to be a significant denominator for IIEF (p = 2.5 × 10- 15) with an R2 of 35%. Variable selection performed using the Akaike information criterion led to a final prediction model for postoperative IIEF after nerve-preservation based on the FP score. Furthermore, patient's age, preoperative IIEF score, CCIS and use of clips for nerve sparing were significantly associated with postoperative IIEF-EF. More anterior fascia preservation was correlated with better EF outcome and age was a strong independent predictor of EF outcome. In older men, the relative benefit of more extensive fascia preservation was at least similar to younger men, despite a lower baseline IIEF-EF score. Quantitative nerve-sparing FP scoring could be related to the postoperative IIEF-EF and integrated into a multivariate prediction model, which includes with age, use of surgical clips, the Charlson Comorbidity Index Score (CCIS), and preoperative IIEF-EF. When further validated the prediction model could provide patients and care-givers a qualitative estimation of EF outcome after RARP.


Assuntos
Disfunção Erétil/epidemiologia , Disfunção Erétil/etiologia , Fáscia , Modelos Estatísticos , Tratamentos com Preservação do Órgão , Complicações Pós-Operatórias/etiologia , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Estudos de Coortes , Disfunção Erétil/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Ereção Peniana/fisiologia , Valor Preditivo dos Testes , Prostatectomia/efeitos adversos , Recuperação de Função Fisiológica/fisiologia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Resultado do Tratamento
10.
Eur J Nucl Med Mol Imaging ; 45(11): 1915-1925, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29696442

RESUMO

PURPOSE: Hybrid image-guided surgery technologies such as combined radio- and fluorescence-guidance are increasingly gaining interest, but their added value still needs to be proven. In order to evaluate if and how fluorescence-guidance can help realize improvements beyond the current state-of-the-art in sentinel node (SN) biopsy procedures, use of the hybrid tracer indocyanine green (ICG)-99mTc-nancolloid was evaluated in a large cohort of patients. PATIENTS AND METHODS: A prospective trial was conducted (n = 501 procedures) in a heterogeneous cohort of 495 patients with different malignancies (skin malignancies, oral cavity cancer, penile cancer, prostate cancer and vulva cancer). After injection of ICG-99mTc-nanocolloid, SNs were preoperatively identified based on lymphoscintigraphy and SPECT/CT. Intraoperatively, SNs were pursued via gamma tracing, visual identification (blue dye) and/or near-infrared fluorescence imaging during either open surgical procedures (head and neck, penile, vulvar cancer and melanoma) or robot assisted laparoscopic surgery (prostate cancer). As the patients acted as their own control, use of hybrid guidance could be compared to conventional radioguidance and the use of blue dye (n = 300). This was based on reported surgical complications, overall survival, LN recurrence free survival, and false negative rates (FNR). RESULTS: A total of 1,327 SN-related hotspots were identified on 501 preoperative SPECT/CT scans. Intraoperatively, a total number of 1,643 SNs were identified based on the combination of gamma-tracing (>98%) and fluorescence-guidance (>95%). In patients wherein blue dye was used (n = 300) fluorescence-based SN detection was superior over visual blue dye-based detection (22-78%). No adverse effects related to the use of the hybrid tracer or the fluorescence-guidance procedure were found and outcome values were not negatively influenced. CONCLUSION: With ICG-99mTc-nanocolloid, the SN biopsy procedure has become more accurate and independent of the use of blue dye. With that, the procedure has evolved to be universal for different malignancies and anatomical locations.


Assuntos
Período Pré-Operatório , Biópsia de Linfonodo Sentinela/métodos , Humanos , Período Intraoperatório
11.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28780044

RESUMO

The integration of medical imaging technologies into diagnostic and therapeutic approaches can provide a preoperative insight into both anatomical (e.g. using computed tomography, magnetic resonance imaging, or ultrasound), as well as functional aspects (e.g. using single photon emission computed tomography, positron emission tomography, lymphoscintigraphy, or optical imaging). Moreover, some imaging modalities are also used in an interventional setting (e.g. computed tomography, ultrasound, gamma or optical imaging) where they provide the surgeon with real-time information during the procedure. Various tools and approaches for image-guided navigation in cancer surgery are becoming feasible today. With the development of new tracers and portable imaging devices, these advances will reinforce the role of interventional molecular imaging.


Assuntos
Invenções , Neoplasias/diagnóstico por imagem , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Sistemas Computacionais , Feminino , Corantes Fluorescentes/análise , Humanos , Laparoscopia , Medições Luminescentes , Masculino , Imagem Multimodal , Metástase Neoplásica , Neoplasias/cirurgia , Cuidados Pré-Operatórios , Radiografia Intervencionista/tendências , Compostos Radiofarmacêuticos , Procedimentos Cirúrgicos Robóticos , Biópsia de Linfonodo Sentinela , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Cirurgia Assistida por Computador/tendências
12.
Nanoscale ; 9(47): 18619-18623, 2017 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-29182183

RESUMO

The hierarchically controlled synthesis and characterization of self-assembling macromolecules and particles are key to explore and exploit new nanomaterials. Here we present a versatile strategy for constructing particle-in-a-box-in-a-box systems by assembling dendrimer-encapsulated gold nanoparticles (DENs) into dendrimicelles. This is realized by combining positively charged PAMAM dendrimers with a negative-neutral block copolymer. The number of particles per dendrimicelle can be controlled by mixing DENs with empty PAMAM dendrimers. The dendrimicelles are stable in solution for months and provide improved resistance for the nanoparticles against degradation. The dendrimicelle strategy provides a flexible platform with a plethora of options for variation in the type of nanoparticles, dendrimers and block copolymers used, and hence is tunable for applications ranging from nanomedicine to catalysis.

13.
Urologe A ; 56(1): 13-17, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27853841

RESUMO

BACKGROUND: Nodal metastases are linked to poor outcome in men with penile or prostate cancer. Early detection and resection are important for staging and for the prognosis. However, lymphadenectomy is associated with morbidity and may miss metastases when performed solely on the basis of anatomical templates. METHODS: In this article we describe the technique and benefits of sentinel node biopsy (SNB) and provide a review of the literature. RESULTS: Dynamic sentinel node techniques using both radioactive and optical (hybrid) tracers have been proven effective in penile cancer. For prostate cancer, SNB added to extended nodal dissection may further tailor dissection to the highly variable lymphatic drainage patterns in the pelvis. The sensitivity of SNB was found to be superior to conventional imaging methods; however, false-negative SNB procedures can occur and a complementary extensive lymphadenectomy is required to remove additional positive nodes that were not detected in the SNB template. CONCLUSION: SNB is a standard method for early detection of nodal metastases in penile cancer and provides superior diagnostic accuracy to conventional imaging modalities in prostate cancer.


Assuntos
Neoplasias Penianas/patologia , Neoplasias da Próstata/patologia , Biópsia de Linfonodo Sentinela/métodos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Detecção Precoce de Câncer/métodos , Humanos , Biópsia Guiada por Imagem/métodos , Metástase Linfática , Masculino , Neoplasias Penianas/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Rev Esp Med Nucl Imagen Mol ; 35(5): 292-7, 2016.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27174865

RESUMO

PURPOSE: To assess if combined fluorescence- and radio-guided occult lesion localization (hybrid ROLL) is feasible in patients scheduled for surgical resection of non-palpable (18)F-FDG-avid lesions on PET/CT. METHODS: Four patients with (18)F-FDG-avid lesions on follow-up PET/CT that were not palpable during physical examination but were suspected to harbor metastasis were enrolled. Guided by ultrasound, the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid was injected centrally in the target lesion. SPECT/CT imaging was used to confirm tracer deposition. Intraoperatively, lesions were localized using a hand-held gamma ray detection probe, a portable gamma camera, and a fluorescence camera. After excision, the gamma camera was used to check the wound bed for residual activity. RESULTS: A total of six (18)F-FDG-avid lymph nodes were identified and scheduled for hybrid ROLL. Comparison of the PET/CT images with the acquired SPECT/CT after hybrid tracer injection confirmed accurate tracer deposition. No side effects were observed. Combined radio- and fluorescence-guidance enabled localization and excision of the target lesion in all patients. Five of the six excised lesions proved tumor-positive at histopathology. CONCLUSION: The hybrid ROLL approach appears to be feasible and can facilitate the intraoperative localization and excision of non-palpable lesions suspected to harbor tumor metastases. In addition to the initial radioguided detection, the fluorescence component of the hybrid tracer enables high-resolution intraoperative visualization of the target lesion. The procedure needs further evaluation in a larger cohort and wider range of malignancies to substantiate these preliminary findings.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Verde de Indocianina , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Adulto , Idoso , Feminino , Doença de Hodgkin/patologia , Humanos , Melanoma/secundário , Imagem Multimodal
15.
Rev Esp Med Nucl Imagen Mol ; 33(5): 274-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24842707

RESUMO

PURPOSE: Recent innovations such as preoperative SPECT/CT, intraoperative imaging using portable devices and a hybrid tracer were evaluated in a multimodality approach for sentinel node (SN) mapping and biopsy in head and neck malignancies. MATERIAL AND METHODS: The evaluation included 25 consecutive patients with head and neck malignancies (16 melanomas and 9 oral cavity squamous cell carcinomas). Patients were peritumorally injected with the hybrid tracer ICG-(99m)Tc-nanocolloid. SNs were initially identified with lymphoscintigraphy followed by single photon emission computed tomography (SPECT/CT) 2 hours after tracer administration. During surgery a portable gamma camera in combination with a near-infrared fluorescence camera was used in addition to a handheld gamma ray detection probe to locate the SNs. RESULTS: In all patients the use of conventional lymphoscintigraphy, SPECT/CT and the additional help of the portable gamma camera in one case were able to depict a total of 67 SNs (55 of them visualized on planar images, 11 additional on SPECT/CT and 1 additional with the portable gamma camera). A total of 67 of the preoperatively defined SNs together with 22 additional SNs were removed intraoperatively; 12 out of the 22 additional SNs found during operation were located in the vicinity of the injection site in anatomical areas such as the periauricular or submental regions. The other 10 additional SNs were found by radioguided post-resection control of the excision SN site. CONCLUSION: In the present series 26% additional SNs were found using the multimodal approach, that incorporates SPECT/CT and intraoperative imaging to the conventional procedure. This approach appears to be useful in malignancies located close to the area of lymphatic drainage such as the periauricular area and the oral cavity.


Assuntos
Câmaras gama , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Linfocintigrafia , Imagem Multimodal , Biópsia de Linfonodo Sentinela/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Bioconjug Chem ; 24(12): 1971-89, 2013 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-24200346

RESUMO

Bacterial infections have always been, and still are, a major global healthcare problem. For accurate treatment it is of upmost importance that the location(s), severity, type of bacteria, and therapeutic response can be accurately staged. Similar to the recent successes in oncology, tracers specific for molecular imaging of the disease may help advance patient management. Chemical design and bacterial targeting mechanisms are the basis for the specificity of such tracers. The aim of this review is to provide a comprehensive overview of the molecular imaging tracers developed for optical and nuclear identification of bacteria and bacterial infections. Hereby we envision that such tracers can be used to diagnose infections and aid their clinical management. From these compounds we have set out to identify promising targeting mechanisms and select the most promising candidates for further development.


Assuntos
Infecções Bacterianas/diagnóstico , Imagem Molecular/métodos , Traçadores Radioativos , Animais , Bactérias/citologia , Bactérias/efeitos dos fármacos , Bactérias/metabolismo , Bactérias/virologia , Infecções Bacterianas/tratamento farmacológico , Humanos , Marcação por Isótopo
17.
Gynecol Oncol ; 131(3): 720-5, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24051219

RESUMO

INTRODUCTION: Conventional sentinel node (SN) mapping is performed by injecting a radiocolloid followed by lymphoscintigraphy (and SPECT/CT imaging). An extra intraoperative injection with blue dye can then allow for optical identification of the SN. In order to improve the current clinical standard, the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid was introduced, a tracer that is both radioactive and fluorescent. This feasibility study aimed to evaluate the value of a multimodal-based SN biopsy in vulvar cancer. MATERIALS AND METHODS: Fifteen patients with vulvar cancer (29 groins) scheduled for SN biopsy were peritumorally injected with ICG-(99m)Tc-nanocolloid followed by lymphoscintigraphy and SPECT/CT imaging to identify the SNs. In thirteen patients, shortly before the start of the operation, blue dye was intradermally injected around the lesion. SNs were harvested using a combination of radiotracing, fluorescence imaging, and optical blue dye detection. A portable gamma camera was used before and after SN excision to confirm excision of the preoperatively defined SNs. RESULTS: Preoperative lymphoscintigraphy and SPECT/CT imaging visualized drainage to 39 SNs in 28 groins. During the operation, 98% (ex vivo 100%) of the SNs were radioactive. With fluorescence imaging 96% of the SNs (ex vivo 100%) could be visualized. Only 65% of the SNs had stained blue at the time of excision. CONCLUSION: ICG-(99m)Tc-nanocolloid can be used for preoperative SN identification and enables multimodal (radioactive and fluorescent) surgical guidance in patients with vulvar cancer. The addition of fluorescence-based optical guidance offers more effective SN visualization compared to blue dye.


Assuntos
Linfonodos/patologia , Linfonodos/cirurgia , Neoplasias Vulvares/patologia , Neoplasias Vulvares/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Verde de Indocianina , Linfonodos/diagnóstico por imagem , Pessoa de Meia-Idade , Imagem Multimodal , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Neoplasias Vulvares/diagnóstico por imagem , Adulto Jovem
18.
Br J Surg ; 100(8): 1037-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23696463

RESUMO

BACKGROUND: Combining radioactive colloids and a near-infrared (NIR) fluorophore permits preoperative planning and intraoperative localization of deeply located sentinel lymph nodes (SLNs) with direct optical guidance by a single lymphatic tracer. The aim of this clinical trial was to evaluate and optimize a hybrid NIR fluorescence and radioactive tracer for SLN detection in patients with breast cancer. METHODS: Patients with breast cancer undergoing SLN biopsy were enrolled. The day before surgery, a periareolar injection of indocyanine green (ICG)-99mTc-radiolabelled nanocolloid was administered and a lymphoscintigram acquired. Blue dye was injected immediately before surgery. Intraoperative SLN localization was performed using a γ probe and the Mini-FLARE™ NIR fluorescence imaging system. Patients were divided into two dose groups, with one group receiving twice the particle density of ICG and nanocolloid, but the same dose of radioactive 99mTc. RESULTS: Thirty-two patients were enrolled in the trial. At least one SLN was identified before and during operation. All 48 axillary SLNs could be detected by γ tracing and NIR fluorescence imaging, but only 42 of them stained blue. NIR fluorescence imaging permitted detection of lymphatic vessels draining to the SLN up to 29 h after injection. Doubling the particle density did not yield a difference in fluorescence intensity (median 255 (range 98-542) versus 284 (90-921) arbitrary units; P = 0.590) or signal-to-background ratio (median 5·4 (range 3·0-15·4) versus 4·9 (3·5-16·3); P = 1·000) of the SLN. CONCLUSION: The hybrid NIR fluorescence and radioactive tracer permitted accurate preoperative and intraoperative detection of the SLNs in patients with breast cancer. REGISTRATION NUMBER: NTR3685 (Netherlands Trial Register; http://www.trialregister.nl).


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Corantes , Feminino , Fluorescência , Humanos , Biópsia Guiada por Imagem , Verde de Indocianina , Cuidados Intraoperatórios/métodos , Metástase Linfática , Linfocintigrafia/métodos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Agregado de Albumina Marcado com Tecnécio Tc 99m
19.
Rev Esp Med Nucl Imagen Mol ; 32(4): 227-33, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23567320

RESUMO

INTRODUCTION: Indocyanine green (ICG)-(99m)Tc-nanocolloid is a novel hybrid fluorescent radioactive tracer for sentinel node (SN) biopsy. This study has aimed to evaluate the added value of this novel versatile tracer in a series of patients with different malignancies. MATERIAL AND METHODS: Twenty patients (with penile carcinoma, oral cavity tumors, melanoma) were consecutively included between March-May 2012. Planar lymphoscintigraphy was performed 15 min and 2h after injection of ICG-(99m)Tc-nanocolloid followed by SPECT/CT. Blue dye (1 ml) was injected in 14 patients in surgery room. Intraoperatively, SNs were localized using a gamma probe and visualized by optical SN-detection using blue dye and fluorescence imaging. Finally, a portable gamma camera was used to confirm complete SN removal. RESULTS: At least one SN was identified by SPECT/CT in all patients. All SNs (total 68, 100%) were excised using a combination of radio- and fluorescence guidance: 89.7% were intraoperatively localized with the gamma probe. The remaining SNs, located near the injection site, were localized using fluorescence imaging. During the surgery, 97% of the SNs were fluorescent while only 39.2% were stained blue. Ex vivo, all SNs were both radioactive and fluorescent. The SN was positive in 5 patients. CONCLUSION: Synchronous radio- and fluorescence guided SN biopsy is feasible using ICG-(99m)Tc-nanocolloid. This hybrid approach combines the beneficial properties of both modalities. Adding fluorescence imaging improves optical SN detection compared to blue dye. It has been shown to be especially useful in the localization of SNs near the injection site.


Assuntos
Corantes , Verde de Indocianina , Biópsia de Linfonodo Sentinela/métodos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Adulto , Idoso , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...